What is the maintenance of discharger?

Time:2021-01-25 16:53   Author:admin Hits:610

The discharger needs to be maintained after it has been used for a period of time. Regular maintenance and repair can help us use the discharger better and prolong its service life. So how to maintain the discharger? Today, Tianlan environmental protection editor tells us:


1. If the discharger uses the just in time ash cleaning controller, it is necessary to regularly determine whether the ash cleaning cycle is correct, otherwise it should be adjusted. When using the constant resistance pulse controller, it is necessary to check the condition of the pressure switch regularly and check whether the pressure tap is blocked.


2. Measure the process parameters regularly, such as smoke volume, temperature, concentration, etc. if any abnormality is found, find out the cause and deal with the reward and punishment in real time.


3. When starting up, the compressed atmosphere should be connected to the air tank, the control power should be connected, and the ash removal assembly should be started. If there is another configuration in the system, the cheap configuration should be started first.


4. If the electromagnetic pulse valve is obstructed, it should be removed in real time. If there are impurities and moisture inside, it should be cleaned up. If the diaphragm is damaged, it should be replaced in real time.


5. The oil-water evacuator in the gas storage tank and gas source triplet should be drained once per shift, and the oil-water evacuator should be washed every 3-6 months. The oil mist device should be checked for oil storage and refueled in real time.


6. When the discharger is shut down, after the process system is stopped, the connection between the adjacent star discharger and the exhaust fan should be carried out for a period of time to remove the moisture and dust in the configuration. It must be careful that when the discharger is stopped, the star discharger must be cleaned repeatedly (manual cleaning can be used), and the dust on the dust removal filter bag must be cancelled, so as to prevent the bag from being pasted due to the influence of moisture It's a little bit hard.


7. When shutdown, it is not necessary to cut off the compressed air source, especially in the case of fan, it is necessary to supply compressed atmosphere to the cylinder of the lift valve to ensure that the lift valve is open.


copyright 2016-2020 Ruian Tianlan environmental protection equipment Co., Ltd all right
Technical support:Hangzhou Nanhao Network Technology Co., Ltd
Contacts:Mr Zhan Tel:0577-65007068 Fax:0577-65007078
Phone:13335773555 Address: No. 111, East 2nd Road, high tech Zone, Ge Xiang, Rui'an City, Zhejiang Province
Website:www.ratlhb.com ICP:Zhejiang ICP no.16043010-2

0.119544s